Sign In | Join Free | My disqueenfrance.com |
|
Model Number : FCM2630-C01
MOQ : 1
Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
Delivery Time : 3-5work days
Target gases : Refrigerant gas R-32
Circuit voltage : 5.0±0.2V DC
Output voltage : 3.50V typical in 5000ppm R-32 Malfunction condition: VOUT < 0.05V or VOUT > 4.95V (Vc = 5.00V)
Reference voltage : 3.50±0.10V at 20˚C Malfunction condition: VREF < 2.50V or VREF > 3.70V (Vc = 5.00V)
Initial alarm accuracy : 2800~7000ppm R-32 (under standard test conditions) Alarm state: VOUT ≥ VREF Normal state: VOUT < VREF
Warm-up time : ≤60 seconds (time before VOUT < VREF after power is turned on in a clean atmosphere)
FCM2630-C01 Gas Sensor Module Pre-calibrated Module Is Used For Refrigerant Leak Detection In Refrigeration Systems Refrigerant Gases R-32 Factory Calibrated Analog Output
Features:
* Factory calibrated
* Temperature compensation circuit
* Resistant to interference gases
* Analog output
* Meets IEC60335-2-40 and JRA4068 requirements
Applications:
* Refrigerant gas leak detection in air
conditioning/refrigeration systems
FCM2630-C01* is an embedded type module using the semiconductor gas
sensor TGS2630 which is optimized to detect A2L refrigerant gas R-32.
This module enables users to easily build a reliable gas leakage detection
system by eliminating electronic circuit design for temperature compensation
and the calibration process. In addition, a connector allows easy replacement
of the gas sensor module for periodic maintenance.
The TGS2630 gas sensor has a built-in filter to reduce the influence of alcohol
and other interference gases, resulting in high selectivity to R-32. For more
detailed information on the gas sensor, including sensitivity characteristics,
see TGS2630 Product Information.
FCM2630-C01 is capable of satisfying the IEC60335-2-40 Edition 6.0 Annex LL and the JRA4068:2021
(Performance 3) standards. The applicable standards are both limited to refrigerant gas type R-32.
* FCM Series is the model name of refrigerant gas sensor modules supplied by Figaro Engineering Inc.
Power consumption | approx. 0.3W |
Weight | approx. 4g |
Dimensions | 25 x 25 x 16mm |
Test gas conditions | 20˚±2˚C, 65±5%RH |
Circuit conditions | Vc = 5.00±0.05V DC |
![]() |